Project Overview
Anchoring Rope and Rigging was engaged by Oxy Petroleum and Cape PLC to develop and deliver a retrofit anchoring solution for a mechanically stabilised earth wall showing signs of failure.
The project required a system capable of strengthening the existing MSE wall without dismantling the wall panels or interrupting surrounding operations. Access was highly restricted, and all work had to be completed under a controlled work-to-permit environment.
AR+R manufactured and supervised the installation of 168 HULK H110 percussion-driven earth anchors, each fitted with a 5.5-metre stainless steel tendon, pattress plate and wedge-grip assembly.
The completed system provided a practical means of tying the existing wall face back into the retained ground and restoring the required structural restraint.
Project Details
Application: Retrofitting and stabilisation of an existing MSE wall
Scope: Manufacture, supply, installation supervision, testing and lock-off
Anchor installation depth: 5 metres
Tendon material: Stainless steel
Load-transfer system: Pattress plates and wedge grips
Installation method: Handheld equipment
The Challenge
The existing mechanically stabilised earth wall required remedial strengthening while remaining largely intact.
Traditional repair methods may have required partial demolition, excavation behind the wall, large drilling equipment or substantial temporary works. These options would have introduced significant cost, disruption and construction risk.
The site also imposed several practical limitations:
- Restricted working space adjacent to the wall
- Limited access for large plant and drilling rigs
- Work-to-permit operational controls
- The need to work through existing MSE wall panels
- A requirement to verify anchor capacity before full production commenced
- The need to achieve consistent performance across 168 anchor locations
The retrofit solution therefore needed to offer high installed capacity while remaining compact, repeatable and practical to construct.
The HULK Earth Anchoring Solution
HULK H110 percussion-driven earth anchors were selected as the preferred retrofit system.
Each anchor was installed through the existing wall face and driven into the retained soil behind the MSE panels. Once installed, the anchors were set within the ground to develop the required resistance.
The anchors were connected to 5.5-metre stainless steel tendons, which extended back through the wall panels. Pattress plates and wedge grips were then fitted to the face of the wall, allowing the restraint loads to be distributed across the existing panels.
This created a direct mechanical connection between the wall face and the stable soil mass behind it.
The system allowed the existing wall to be strengthened without large-scale excavation or removal of the MSE panels.
Custom Manufacture and Technical Support
AR+R manufactured the complete anchor assemblies specifically for the project.
The system included:
- HULK H110 percussion anchors
- 5.5-metre stainless steel tendons
- Pattress plates
- Wedge-grip locking assemblies
- Installation and testing equipment
- Technical supervision throughout the works
The use of stainless steel tendons provided a durable load-transfer element suited to the project environment and the long-term requirements of the retrofit system.
The project was supported by AR+R’s technical and installation experience, ensuring that the anchor configuration, installation sequence and testing methodology were properly developed before production began.
Phase One: Capacity and Methodology Trials
The project was delivered in two distinct phases.
The first phase focused on confirming both the in-situ anchor capacity and the proposed installation methodology.
Trial anchors were installed through the existing MSE wall panels and tested under actual site conditions. This allowed the project team to assess:
- The performance of the H110 anchors within the retained soils
- The most effective coring and installation sequence
- The suitability of the handheld installation equipment
- The required testing and stressing procedures
- The performance of the pattress plate and wedge-grip system
- The practicality of completing the works within the available space
This initial phase reduced construction risk and confirmed that the HULK system could achieve the required performance before the full production installation commenced.
Phase Two: Production Installation
Following successful completion of the trial phase, the project moved into full production.
Holes were cored through the existing MSE wall panels at the nominated anchor locations. The HULK H110 anchors were then driven through the cored openings and installed to a depth of 5 metres.
Once each anchor had been installed and set, the stainless steel tendon was fitted with a pattress plate and wedge grip at the wall face.
The completed assemblies were then stressed to the specified test loads before being locked off at the required working load.
This process was repeated across all 168 anchor locations, creating a consistent tie-back system across the affected sections of the wall.
Installation with Handheld Equipment
One of the key advantages of the HULK percussion-driven system was its ability to be installed entirely with handheld equipment.
Large drilling rigs and heavy plant could not be practically accommodated within the restricted working areas. The compact HULK installation equipment allowed the crews to operate directly against the wall face while maintaining control over each stage of the work.
The use of handheld tools also reduced the need for extensive access preparation, lifting operations and temporary working platforms.
Despite the compact equipment footprint, the anchors were successfully installed to the required 5-metre depth and developed the capacity needed for the permanent retrofit system.
Testing, Stressing and Lock-Off
Each anchor was tested following installation to confirm its in-situ capacity.
The testing process verified that the anchor had developed sufficient resistance in the retained ground before it was accepted as part of the permanent system.
After successful testing, the anchors were stressed and locked off using the pattress plates and wedge grips.
This applied the required restraining force to the MSE wall and ensured that the wall face, tendons and anchors acted together as an integrated stabilisation system.
Testing each installed anchor provided direct confirmation of performance rather than relying solely on assumed soil parameters or theoretical capacity.
Collaborative Project Delivery
HULK installation crews worked alongside crews from Concrete Canvas to complete the works.
Close coordination was required to manage the coring, anchor installation, testing, stressing and associated wall-remediation activities.
The combined crews completed the project over an approximately four-week period.
The staged methodology and coordinated site operations allowed the works to progress efficiently while maintaining the required permit controls and quality standards.
Project Outcome
The HULK percussion-driven anchoring system provided an effective retrofit solution for the failing MSE wall.
A total of 168 HULK H110 Earth Anchors were successfully installed through the existing wall panels and into the retained ground. Each anchor was fitted with a stainless steel tendon, pattress plate and wedge grip before being tested, stressed and locked off.
The system avoided the need for extensive demolition, excavation or large-scale drilling equipment.
Its compact installation requirements were particularly valuable within the restricted site, where conventional ground anchoring methods would have been difficult to deploy.
Why HULK Earth Anchors Were Selected
HULK Earth Anchors were chosen due to the combination of:
- High installed capacity
- Compact installation equipment
- Suitability for confined work areas
- Ability to install through existing wall panels
- Minimal excavation requirements
- Individual proof testing
- Rapid installation
- Comprehensive technical and installation support
The project demonstrated the effectiveness of HULK Earth Anchors for remedial retaining-wall works, MSE wall retrofits and other projects where existing structures need to be strengthened without major reconstruction.
Backed by AR+R’s practical experience and technical resources, the HULK system delivered the buildability, verified performance and operational flexibility required for this challenging project.